Specification is as follows:
Model: |
IV2-90 |
Dimensions of the work zone in mm : |
610 x 420 x 350 |
Maximum load (at 900 oC) in Kg : |
120 |
Max. temperature : |
1300 |
Uniformity of furnace temperature (+-oC) |
5 |
Ultimate vacuum in Pa: |
4x10-1 |
Vacuum leakage in Pa/h: |
0.67 |
Heating power (KW) : |
65 |
Power of motor in horizontal operation (KW): |
0.75 |
Power of motor in Vertical operation (KW): |
1.8/3 |
Power of motor for oil stirring (KW): |
1.1 |
Power of air-cool fan (KW): |
7.5 |
Power of vacuum unit (KW): |
11 |
Oil heating Power (KW): |
9 |
Installed power (KW): |
115 |
Air-cool pressure intensity in bar: |
<2 (absolute pressure) |
Nitrogen consumption (1bar) (Nm3): |
2 |
Water consumption (m3/h): |
4 |
Overall weight (T): |
9 |
Footprint in m2 |
20 |